National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
Compact inverter for BLDC motor
Nevřivý, Tomáš ; Červinka, Dalibor (referee) ; Procházka, Petr (advisor)
The work describes the design and implementation of compact inverter for brushless DC motor, which have mechanical power 600 W and rated torque 1.6 Nm. Motor is designed for DC link voltage with value 300 V. The focus is placed on the cost and simplicity. On this basis, the inverter is designed for uses single purpose power and control circuit. The power part is solved using a circuit FSBB15CH60C. The circuit is placed on a separate board of power electronics. Cooling of the power circuit is performed by the surface structure of BLDC motor. Control of the inverter ensures circuits LB11696V and NE566. The both circuits are placed on separate board of control electronics. Circuit LB11696V contains a control algorithm, as well as protections, which are necessary for safe operation of the inverter. Power supply of electronics is performed using step-down converter from MYRRA company.
Development of a Novel Terahertz Magnetic Resonance Spectrometer for Spin Dynamics Investigations
Sojka, Antonín ; Smith, Graham Murray (referee) ; Tseytlin, Mark (referee) ; Neugebauer, Petr (advisor)
Během posledních desetiletí zaznamenala metoda nazývaná vysokofrekvenční elektronová paramagnetická rezonance (HF-EPR) rozmach v chemii, biologii, materiálových vědách a fyzice. Přesto jsou HF-EPR spektrometry pracující na frekvencích blížící se THz ve světě vzácné. Cílem této dizertační práce bylo vyvinout nový širokopásmový EPR spektrometr schopný pracovat jak v širokém magnetickém poli tak v široké frekvenční oblasti a který by byl schopen provádět rychlé skenování frekvencí pro studium relaxačních časů. Vyvinutý spektrometr pracuje při magnetických polích 0-16 T, frekvenční rozsah od 90 do 1100 GHz a teplotní rozsahy 4 – 400 K. V práci je dále popsán návrh a vývoj šesti různých výměnných držáků vzorků s EPR měřeními, které prokázali jejich funkčnosti. Design obsahuje navíc unikátní rychloupínací přírubou pro rychlou výměnu vzorku společně s držákem vzorku. Schopnost spektrometru provádět rychlé skenování frekvence pro měření relaxačních časů je demonstrována na měření LiPc monokrystalu a vzorku DPPH rozpuštěného v toluenu.
Development of a Novel Terahertz Magnetic Resonance Spectrometer for Spin Dynamics Investigations
Sojka, Antonín ; Smith, Graham Murray (referee) ; Tseytlin, Mark (referee) ; Neugebauer, Petr (advisor)
Během posledních desetiletí zaznamenala metoda nazývaná vysokofrekvenční elektronová paramagnetická rezonance (HF-EPR) rozmach v chemii, biologii, materiálových vědách a fyzice. Přesto jsou HF-EPR spektrometry pracující na frekvencích blížící se THz ve světě vzácné. Cílem této dizertační práce bylo vyvinout nový širokopásmový EPR spektrometr schopný pracovat jak v širokém magnetickém poli tak v široké frekvenční oblasti a který by byl schopen provádět rychlé skenování frekvencí pro studium relaxačních časů. Vyvinutý spektrometr pracuje při magnetických polích 0-16 T, frekvenční rozsah od 90 do 1100 GHz a teplotní rozsahy 4 – 400 K. V práci je dále popsán návrh a vývoj šesti různých výměnných držáků vzorků s EPR měřeními, které prokázali jejich funkčnosti. Design obsahuje navíc unikátní rychloupínací přírubou pro rychlou výměnu vzorku společně s držákem vzorku. Schopnost spektrometru provádět rychlé skenování frekvence pro měření relaxačních časů je demonstrována na měření LiPc monokrystalu a vzorku DPPH rozpuštěného v toluenu.
Comparing values of sedimentation of erythrocytes of lipid complex
ŠTEFKOVÁ, Michaela
The aim of this work is to compare the values of erythrocytes sedimentation rate (ESR) of the ESR obtained by the stop flow method with the individual values of lipid complex. Verify that ESR values are affected by hyperlipoproteinemia. Correlation coefficients are calculated and correlation dependence graphs between ESR values and lipid assay parameters (TAG, TC, HDL and LDL) are compiled.
Comparison of surface ferritin with levels of CRP and erythrocyte sedimentation rate as markers of acute-phase inflammation.
STRUČKOVÁ, Daniela
The aim of the study is to compare the levels of ferritin, CRP and the rate of erythrocyte sedimentation. Ferritin and CRP belong to the acute phase proteins that are formed in increased levels in inflammatory conditions and certain diseases. CRP is one of the most important markers of acute phase inflammation for high sensitivity, it is increasing hours after the onset of the acute phase reaction and rises more than a hundred times during the first days. CRP was measured on a Beckman Coulter AU 680 analyzer using the reaction of antigen-antibody and photometric measurements. The ferritin measurement on the Architect analyzer is a two-stage immunoassay of the immunological chemiluminescent microparticle using. The resulting reaction is measured in the optical system. Examination of the rate of erythrocyte sedimentation is frequent, although not specific to a particular disease. However, it can be used in diagnosing or monitoring of the effect therapy efficiency. The principle of measuring on Alifax Test analyzer is monitoring the aggregate capacity of red cells through optical density. These three parameters were measured by 1000 patients, the ratios of all measured values were calculated and compared with each other by means of linear regression graphs and the calculated correlation coefficients. The correlation coefficients have shown a low degree of dependence between ferritin and CRP and between CRP and age. The medium degree of dependence was proofed between ferritin and ESR parameters, between CRP and ESR and between age and ferritin, and age and ESR. All samplies were performed lege artis according to the instructions of the standard operating procedure of the company synlab czech, s.r.o. After collecting, these samples were measured in the laboratory synlab czech, s.r.o., Vrbenská 197/23, České Budějovice.
Compact inverter for BLDC motor
Nevřivý, Tomáš ; Červinka, Dalibor (referee) ; Procházka, Petr (advisor)
The work describes the design and implementation of compact inverter for brushless DC motor, which have mechanical power 600 W and rated torque 1.6 Nm. Motor is designed for DC link voltage with value 300 V. The focus is placed on the cost and simplicity. On this basis, the inverter is designed for uses single purpose power and control circuit. The power part is solved using a circuit FSBB15CH60C. The circuit is placed on a separate board of power electronics. Cooling of the power circuit is performed by the surface structure of BLDC motor. Control of the inverter ensures circuits LB11696V and NE566. The both circuits are placed on separate board of control electronics. Circuit LB11696V contains a control algorithm, as well as protections, which are necessary for safe operation of the inverter. Power supply of electronics is performed using step-down converter from MYRRA company.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.